Device Photos
Front
Back
×
Basic data
Name
CS Schallner PA 1200M
Category
19) Monitoring / measurement / service engineering
Type
MONITORING_UNIT
Specimen
A
Inventory tag
HW-2024-MON-SCHALLNER-001
Condition
OK
Physical parameters
Dimensions (mm)
—
Dimensions (inch)
—
Weight
—
Format
—
Material
—
Manufacturing (Period)
—
Manufacturer
—
Power
Voltage
230V AC (primary) or 24V DC (emergency)
Current (typical)
0.065 A @ 230V AC
Current (max)
0.5 A @ 24V DC
Polarity
N/A
Connector
AC power cable, DC csatlakozo for emergency power supply
AC/DC
AC / DC
Internal/External
Internal
Note
15 VA booby trap. Temperature range 0- 40 ° C. Duplex power supply for rugged.
Warning: Check the polarity of the source before connecting! Improper power supply will damage the device.
Firmware and serial number
Serial number
Not stated
FW version (current)
Hardware
Check date
2026-03-03
Previous version
N/A
Bootloader
N/A
Update Link
—
Backup File
—
Quick Summary
11-channel monitoring unit with LED VU meter. 10 monitor inputs 1-100V, 1 aux input, built-in speaker and headphone jack.
Product Description
—
Features and functions
- 11-channel monitoring capacity - 10 monitors + 1 aux
- 10 monitor inputs - 1-100V impedance - universal compatibility
- 1 auxiliary input - 0.775V (-10 dBV) - standard signals
- Rotary input switch - easy selection of channel
- LED VU meter - 10 * visual signal monitor
- Clip LED - backlight over-drawing signal (red)
- Built-in 2W speaker - built-in monitoring
- 6.3 mm headphones jack - personal monitoring
- Individual volume control - speaker + headphones are not paired
- Duplex power supply - 230V AC + 24V DC emergency
- 0.065 A @ 230V - low energy consumption
- Temperature range 0- 40 ° C - robust design
- < 0.3% THD - clean monitoring sound
- Frequency range 100 Hz - 20 kHz
- Vintage design - classic monitoring unit from 70. / 80. years
Primary I/O (quick orientation)
| Domain | Inputs | Outputs | Note |
| Inputs Monitor | 10 × screw clamps (1-100V / 10 kCalculation) | — | 10 monitor channels with individual selection via rotary switch |
| Aux Input | Screw clamps (0.775V / 600 Calculation) | — | 1 auxiliary input for alternative source |
| Output | — | 2W built-in speaker + 6.3 mm Jack headphones | Stereo monitoring and headphone output with individual volume control |
Controls
FRONT / TOP (user control)
- Rotary input switch for channel selection (1-10 monitor + aux)
- Volume controller for built-in speaker
- Volume controller for headphones (6.3 mm jack)
- LED VU meter for each input
- Clip LED for channel overload control (red)
- Power switch + on indicator
Service / hidden elements
Connectors and connections
Connector matrix
| Interfaces | IN | OUT | Spec / note |
| Inputs Monitor | 10 × screw clamps (1-100V / 10 kCalculation) | — | 10 monitor channels with individual selection via rotary switch |
| Aux Input | Screw clamps (0.775V / 600 Calculation) | — | 1 auxiliary input for alternative source |
| Output | — | 2W built-in speaker + 6.3 mm Jack headphones | Stereo monitoring and headphone output with individual volume control |
Latency and jitter
Clock sources
N / A (analog amplifier)
Clock IN/OUT format
N/A
Typical latency
N/A
Jitter spec
N/A
Buffer support
N/A
Impedance and signal levels
Line Level (dBu)
Design input: 1-100V (monitor), 0.775V / -10 dBV (aux)
Mic In level
—
Output Impedance
—
Input Impedance
10 kCalculation (monitor), 600 Calculation (aux)
THD
< 0.3%
Frequency Range
100 Hz - 20 kHz
Other Specifications (from metadata.specifications)
| Key | Value |
| No other specifications |
Additional technical details
| Key | Value |
| No additional technical details |
Typical routing
- Multi-channel resource monitoring: Monitoring mix from 10 different sound sources
• Connect 1-10 resources to screw input terminals (1-100V impedance)
• Set the rotary switch to the desired channel
• Follow LED VU meter for signal level
• Send to speaker or headphones as needed
- Emergency power monitoring: Connection DC 24V source for emergency mode
• Connect 24V DC power supply (0.5A min)
• In case of failure of AC: the unit remains functional
• Monitor DC Power Indicator
• Use for mixing reference in emergency mode
Connection instructions: The examples below show typical signal flows in practice. For specific details (jitter, buffering), see section above.
SW / drivers
| Component | Windows | macOS | Linux | Note |
| No specific driver data; use the Documentation/Links section. |
Custom firmware details
Custom FW targets
- No explicit custom FW targets in metadata.
Custom CC mapping
| CC | Meaning |
| No custom CC mapping. |
Custom FW global settings
| Settings | Meaning |
| No custom global settings. |
Custom FW extended menu
| Item | Detail |
| No extended menu details. |
Documentation and manuals
Manufacturer / Links
Service log
| Date | Event | Who | Note |
| 2026-03-03 | Initial inventory | Studio tech | Added to inventory |
Presets / User banks
Storage type
—
Number of banks
—
Current bank
—
Backup File
—
Export format
—
Note
Hardware without preset
Notes / service / modifications
- Professional monitoring unit for PA systems, TV studios and broadcast
- The AC / DC duplex ensures robust
- LED indication on each channel = easy diagnostics
- Ideal for monitoring input signal and volume monitoring
- Dimensions: 482 × 88 × 200 mm (2 RU rack unit)