Current Studio & HW · / 19) Monitoring / measurement / service engineering
CS Schallner PA 1200M
OK MONITORING_UNIT
Overview Physical parameters Controls Connectors and connections SW / drivers Documentation Manufacturer / Links Notes / Service

Device Photos

Basic data

Name
CS Schallner PA 1200M
Category
19) Monitoring / measurement / service engineering
Type
MONITORING_UNIT
Specimen
A
Inventory tag
HW-2024-MON-SCHALLNER-001
Condition
OK

Physical parameters

Dimensions (mm)
—
Dimensions (inch)
—
Weight
—
Format
—
Material
—
Manufacturing (Period)
—
Manufacturer
—

Power

Voltage
230V AC (primary) or 24V DC (emergency)
Current (typical)
0.065 A @ 230V AC
Current (max)
0.5 A @ 24V DC
Polarity
N/A
Connector
AC power cable, DC csatlakozo for emergency power supply
AC/DC
AC / DC
Internal/External
Internal
Note
15 VA booby trap. Temperature range 0- 40 ° C. Duplex power supply for rugged.
Warning: Check the polarity of the source before connecting! Improper power supply will damage the device.

Firmware and serial number

Serial number
Not stated
FW version (current)
Hardware
Check date
2026-03-03
Previous version
N/A
Bootloader
N/A
Update Link
—
Backup File
—

Quick Summary

11-channel monitoring unit with LED VU meter. 10 monitor inputs 1-100V, 1 aux input, built-in speaker and headphone jack.

Product Description

—

Features and functions

  • 11-channel monitoring capacity - 10 monitors + 1 aux
  • 10 monitor inputs - 1-100V impedance - universal compatibility
  • 1 auxiliary input - 0.775V (-10 dBV) - standard signals
  • Rotary input switch - easy selection of channel
  • LED VU meter - 10 * visual signal monitor
  • Clip LED - backlight over-drawing signal (red)
  • Built-in 2W speaker - built-in monitoring
  • 6.3 mm headphones jack - personal monitoring
  • Individual volume control - speaker + headphones are not paired
  • Duplex power supply - 230V AC + 24V DC emergency
  • 0.065 A @ 230V - low energy consumption
  • Temperature range 0- 40 ° C - robust design
  • < 0.3% THD - clean monitoring sound
  • Frequency range 100 Hz - 20 kHz
  • Vintage design - classic monitoring unit from 70. / 80. years

Primary I/O (quick orientation)

DomainInputsOutputsNote
Inputs Monitor10 × screw clamps (1-100V / 10 kCalculation)—10 monitor channels with individual selection via rotary switch
Aux InputScrew clamps (0.775V / 600 Calculation)—1 auxiliary input for alternative source
Output—2W built-in speaker + 6.3 mm Jack headphonesStereo monitoring and headphone output with individual volume control

Controls

FRONT / TOP (user control)

  • Rotary input switch for channel selection (1-10 monitor + aux)
  • Volume controller for built-in speaker
  • Volume controller for headphones (6.3 mm jack)
  • LED VU meter for each input
  • Clip LED for channel overload control (red)
  • Power switch + on indicator

Service / hidden elements

  • (None)

Connectors and connections

Connector matrix

InterfacesINOUTSpec / note
Inputs Monitor10 × screw clamps (1-100V / 10 kCalculation)—10 monitor channels with individual selection via rotary switch
Aux InputScrew clamps (0.775V / 600 Calculation)—1 auxiliary input for alternative source
Output—2W built-in speaker + 6.3 mm Jack headphonesStereo monitoring and headphone output with individual volume control

Latency and jitter

Clock sources
N / A (analog amplifier)
Clock IN/OUT format
N/A
Typical latency
N/A
Jitter spec
N/A
Buffer support
N/A

Impedance and signal levels

Line Level (dBu)
Design input: 1-100V (monitor), 0.775V / -10 dBV (aux)
Mic In level
—
Output Impedance
—
Input Impedance
10 kCalculation (monitor), 600 Calculation (aux)
THD
< 0.3%
Frequency Range
100 Hz - 20 kHz

Other Specifications (from metadata.specifications)

KeyValue
No other specifications

Additional technical details

KeyValue
No additional technical details

Typical routing

  • Multi-channel resource monitoring: Monitoring mix from 10 different sound sources
    • Connect 1-10 resources to screw input terminals (1-100V impedance)
    • Set the rotary switch to the desired channel
    • Follow LED VU meter for signal level
    • Send to speaker or headphones as needed
  • Emergency power monitoring: Connection DC 24V source for emergency mode
    • Connect 24V DC power supply (0.5A min)
    • In case of failure of AC: the unit remains functional
    • Monitor DC Power Indicator
    • Use for mixing reference in emergency mode
Connection instructions: The examples below show typical signal flows in practice. For specific details (jitter, buffering), see section above.

SW / drivers

ComponentWindowsmacOSLinuxNote
No specific driver data; use the Documentation/Links section.

Custom firmware details

Author
—
FW family
—

Custom FW targets

  • No explicit custom FW targets in metadata.

Custom CC mapping

CCMeaning
No custom CC mapping.

Custom FW global settings

SettingsMeaning
No custom global settings.

Custom FW extended menu

ItemDetail
No extended menu details.

Documentation and manuals

Service log

DateEventWhoNote
2026-03-03Initial inventoryStudio techAdded to inventory

Presets / User banks

Storage type
—
Number of banks
—
Current bank
—
Backup File
—
Export format
—
Note
Hardware without preset

Notes / service / modifications

  • Professional monitoring unit for PA systems, TV studios and broadcast
  • The AC / DC duplex ensures robust
  • LED indication on each channel = easy diagnostics
  • Ideal for monitoring input signal and volume monitoring
  • Dimensions: 482 × 88 × 200 mm (2 RU rack unit)